Contact Information: 1-800-991-7026 | 1-919-372-8413 | sales@automationindustrial.com
FREE DOMESTIC GROUND SHIPPING! (see shipping policies below for more details)
ALL ORDERS SHIP SAME DAY! (if placed before 3PM EST)
- M/N: F3-08THM-J
- Made By: Facts Engineering
- Unit Family: DirectLogic 305
- Functional Description: Temperature Input Module
- Version: Thermocouple
- Thermocouple Type: J
- Input Resolution: 12 bit
- Impedance: 27KΩ DC
- Maximum Voltage: 130Vrms, 100VDC
- Conversion Time (Per Channel): 15ms
- Minimum Scanned Channels: 1
- ZIPLink: Not Compatible
-
Does the F3-08THM-J have automatic cold junction compensation?
- Yes, this is a feature of this module.
-
How accurate is the F3-08THM-J versus the temperature?
- The F3-08THM-J has an accuracy of 57 parts per million per degree Celsius at max full scale.
-
Does the F3-08THM-J need an external power supply?
- No, this is not needed on the F3-08THM-J.
⭐⭐⭐⭐ 4.0
The F3-08THM-J is made for working with the common J-type thermocouples. While these types of thermocouple are relatively popular, the lack of support for other types makes this module less compatible than similar thermocouple input modules. -Automation Industrial Quality Assurance Manager
Description
General Information about the Product | |
Part Number |
F3-08THM-J F3 |
Description |
F3-08THM-J By Facts Engineering Thermocouple PLC Module DL305 |
Condition |
Pre-Owned Cleaned and Tested. With 1 Year Warranty. |
Technical Specifications | |
| M/N | F3-08THM-J |
| Made By | Facts Engineering |
| Unit Family | DirectLogic 305 |
| Functional Description | Temperature Input Module |
| Version | Thermocouple |
| Thermocouple Type | J |
| Input Resolution | 12 bit |
| Impedance | 27KΩ DC |
| Maximum Voltage | 130Vrms, 100VDC |
| Conversion Time (Per Channel) | 15ms |
| Minimum Scanned Channels | 1 |
| ZIPLink | Not Compatible |
Frequently Asked Questions | |
| Does the F3-08THM-J have automatic cold junction compensation? Yes, this is a feature of this module. | |
| How accurate is the F3-08THM-J versus the temperature? The F3-08THM-J has an accuracy of 57 parts per million per degree Celsius at max full scale. | |
| Does the F3-08THM-J need an external power supply? No, this is not needed on the F3-08THM-J. | |
Internal Review | |
|
⭐⭐⭐⭐
4.0
The F3-08THM-J is made for working with the common J-type thermocouples. While these types of thermocouple are relatively popular, the lack of support for other types makes this module less compatible than similar thermocouple input modules. -Automation Industrial Quality Assurance Manager |
|
Policies and Procedures
Shipping |
We offer FREE DOMESTIC GROUND SHIPPING on all orders unless otherwise specified. In addition to FREE DOMESTIC GROUND SHIPPING we offer UPS Next Day Air Early AM, UPS Next Day Air, UPS 2nd Day Air, and UPS 3-day Select (when applicable). Please contact us at (919) 372-8413 prior to purchase if you would like urgent shipping via any of the above expedited options. |
Returns |
All products ordered from Automation Industrial will come with our 1 YEAR WARRANTY. Any item(s) found to be defective through normal use and wear within 1 Year from the date of receipt are covered under warranty. |
Contact Us |
Contact us at 919-372-8413 or kindly submit a message via the website submission form. We look forward to hearing from you! |
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
You may also like
Recently viewed
- Opens in a new window.