Contact Information: 1-800-991-7026 | 1-919-372-8413 | sales@automationindustrial.com
FREE DOMESTIC GROUND SHIPPING! (see shipping policies below for more details)
ALL ORDERS SHIP SAME DAY! (if placed before 3PM EST)
- Product ID: F4-08RTD
- Part Manufacturer: Facts Engineering
- Family: DirectLogic 405
- Category: Temperature Input Module
- Version: RTD
- Channels: 8
- Supported RTD Types: Pt100, Pt1000, jPT100, CU-10, CU-25
- RTD Excitation Current: 200µA
- Resolution: 16-bit
- Input Impedance: 27kΩ
- Common Mode Range: 0-5VDC
- ZIPLink Compatible: No
-
Are the inputs on the F4-08RTD differential?
- Yes, this module uses differential inputs.
-
What is the maximum settling time rating for the F4-08RTD?
- The F4-08RTD has a maximum settling time of 100 milliseconds.
-
What temperatures are safe for operating the F4-08RTD?
- The F4-08RTD can work in temperatures between 0°C and 60°C.
⭐⭐⭐⭐⭐ 5.0
The F4-08RTD is an excellent RTD input module, as it can support some of the most common platinum and copper inputs used commercially. The input channels on this unit have some of the highest resolution and accuracy ratings among all the DL405 option modules. -Automation Industrial Quality Assurance Manager
Description
General Information about the Product | |
Part Number |
F4-08RTD DirectLogic 405 |
Description |
F4-08RTD by Facts Engineering Temperature Input Module DL405 DirectLOGIC 405 |
Condition |
Pre-Owned Cleaned and Tested. With 1 Year Warranty. |
Technical Specifications | |
| Product ID | F4-08RTD |
| Part Manufacturer | Facts Engineering |
| Family | DirectLogic 405 |
| Category | Temperature Input Module |
| Version | RTD |
| Channels | 8 |
| Supported RTD Types | Pt100, Pt1000, jPT100, CU-10, CU-25 |
| RTD Excitation Current | 200µA |
| Resolution | 16-bit |
| Input Impedance | 27kΩ |
| Common Mode Range | 0-5VDC |
| ZIPLink Compatible | No |
Frequently Asked Questions | |
| Are the inputs on the F4-08RTD differential? Yes, this module uses differential inputs. | |
| What is the maximum settling time rating for the F4-08RTD? The F4-08RTD has a maximum settling time of 100 milliseconds. | |
| What temperatures are safe for operating the F4-08RTD? The F4-08RTD can work in temperatures between 0°C and 60°C. | |
Internal Review | |
|
⭐⭐⭐⭐⭐
5.0
The F4-08RTD is an excellent RTD input module, as it can support some of the most common platinum and copper inputs used commercially. The input channels on this unit have some of the highest resolution and accuracy ratings among all the DL405 option modules. -Automation Industrial Quality Assurance Manager |
|
Policies and Procedures
Shipping |
We offer FREE DOMESTIC GROUND SHIPPING on all orders unless otherwise specified. In addition to FREE DOMESTIC GROUND SHIPPING we offer UPS Next Day Air Early AM, UPS Next Day Air, UPS 2nd Day Air, and UPS 3-day Select (when applicable). Please contact us at (919) 372-8413 prior to purchase if you would like urgent shipping via any of the above expedited options. |
Returns |
All products ordered from Automation Industrial will come with our 1 YEAR WARRANTY. Any item(s) found to be defective through normal use and wear within 1 Year from the date of receipt are covered under warranty. |
Contact Us |
Contact us at 919-372-8413 or kindly submit a message via the website submission form. We look forward to hearing from you! |
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
You may also like
Recently viewed
- Opens in a new window.